Model Number | GTSI-3K3-1H | GTSI-4K0-1H | GTSI-5K0-1H | GTSI-6K0-1H | |
---|---|---|---|---|---|
PV String Input Data | Maximum PV Power at STC | 4.5 kWp | 5.3kWp | 6.6 kWp | 7kWp |
Recommended PV Power at STC | 3.3-4.5 kWp | 4-5.3 kWp | 5-6.6 kWp | 5.5-7kWp | |
Absolute Maximum PV Voltage | 450V | ||||
MPPT Voltage Range | 50-420V | ||||
MPTT Voltage Range for Full Load | 165-420V | 200-420V | 125-420V | 150-420V | |
StartUp Voltage | 100V | ||||
Input DC Voltage Nominal | 320V | ||||
Maximum continuous input current | 20A | ||||
PV Short Circuit Current | 22A | ||||
Number of MPPT Trackers | 1 | 2 | |||
Number of Input Strings per MPPT Tracker | 1 | ||||
MaximumBack-feed current | 0A | ||||
AC Output Data | Rated Output Power | 3.3kW | 4 kW | 5 kW | 6 kW |
Maximum Output Apparent Power | 4.5 kVA (@ maximum output voltage of 264V) | 5.3 kVA (@ maximum output voltage of 264V) | 6.6 kVA (@ maximum output voltage of 264V) | 7.9 kVA (@ maximum output voltage of 264V) | |
Nominal Output Voltage/Range | 240V/(204-264V) | ||||
Nominal Output Frequency/ Range | 50 Hz/(47.5-52 Hz) | ||||
Maximum Continuous Output Current | 17A | 20A | 25A | 30A | |
In-rush current at inverter start-up | 15A (Peak) | ||||
Output Power Factor | Default is Unity (Adjustable from 0.8 leading to 0.8 lagging) | ||||
Output Current THD (@ Nominal output voltage and power) | <2% | <1.8% | <1.5% | <1.25% | |
Active Power Control | 0.3-3.3 kW with 0.1 kW resolution | 0.4-4 kW with 0.1 kW resolution | 0.5-5 kW with 0.1 kW resolution | 0.6-6 kW with 0.1 kW resolution | |
Reactive Power Control | 2 kVAr capacitive to 2 kVAr inductive | 2.4 kVAr capacitive to 2.4 kVAr inductive | 3 kVAr capacitive to 3 kVAr inductive | 3.6 kVAr capacitive to 3.6 kVAr inductive | |
Output Over Current Protection | 22A rms | 26A rms | 32A rms | 38.4A rms | |
Efficiency Data | Maximum Efficiency | 97.7% @ 720V PV Voltage and 2475W solar power | 97.8% @ 720V PV Voltage and 2.5 kW solar power | 98.2% @ 720V PV Voltage and 3kW solar power | |
Efficiency @ Rated Power and rated PV and Grid Voltages | 97.3% | 97.4% | 97.4% | 97.7% | |
Euro Efficiency @ Rated PV and Grid Voltages | 97.7% | 96.5% | 96.8% | 97.2% | |
Euro Efficiency @ Rated Grid Voltage and Averaged over PV Voltage Range | 96.7% | 96.5% | 96.8% | 97.2% | |
Static MPPT Efficiency (EN50530) | 99.8% | ||||
Dynamic MPPT Efficiency (EN50530) | 98.8% | ||||
General Data | IP Protection | IP 65 | |||
Cooling | Natural Air Cooling | ||||
Operating Altitude | <=2000 m | ||||
Operating Temperature | -250C to 550C | ||||
Noise | Less than 25 dB | ||||
Humidity | 5% to 95% | ||||
Night Self consumption for control electronics | Less than 4W | ||||
Topology | Transformerless | ||||
Protective Class | Class I | ||||
Grid Side Connector | 3-pin connector, 25A, IP 68 | ||||
PV Side Connector | MC4 Connector, IP-67 | ||||
Weight | 7 kgs | 9 kgs | 12 kgs | 14 kgs | |
Dimensions | 285 (H) X 300 (W) X 180 (D) all in mm | 350 (H) X 300 (W) X 200 (D) all in mm | |||
Protection | Anti-Islanding Protection | Integrated | |||
Input Reverse Polarity Protection | Integrated | ||||
SPD AC Side | 350 Vac, Type-III SPD Integrated | ||||
SPD DC Side | 1000 Vdc, Type-III SPD Integrated | ||||
Residual Current Monitoring Unit | Integrated | ||||
Output Over Current Protection | Integrated | ||||
Output Short Circuit Protection | Integrated | ||||
Grid Over Voltage Protection | Integrated | ||||
Standards | Safety Standard | IS 16221/IEC 62109-2 | |||
Anti-Islanding | IS 16169/IEC 62116 | ||||
Harmonic Current Control | IEC 61000-3-2 | ||||
Grid Under/Over Voltage Setting | As per CEA India | ||||
Grid Under/Over Frequency Setting | As per CEA India |